CubeMars published a three-minute selection guide on November 27, 2026 that treats the four joints of a humanoid arm as four separate sizing problems. A BLDC motor built into a joint module does not see the same load at the neck as it does at the shoulder, and the CubeMars AK series hardware in the film shows how the constraints change along the arm. This article follows that joint-by-joint reasoning and ties each stage to the published specifications of the three actuators named.

Figures below come from the official CubeMars product pages, where each rating carries its published condition. The aim is a repeatable way to specify a humanoid robot arm actuator joint by joint, not one figure applied to all four positions.

What the Video Shows

The 3:17 film, titled “How to Choose Actuators for a Humanoid Robot Arm | CubeMars AK”, appeared on the official CubeMars YouTube channel on November 27, 2026. It opens on the point that one actuator cannot serve every joint, then moves through neck, shoulder, elbow and wrist in turn, illustrated with the CubeMars AK series, a humanoid platform, and footage of assembly and torque testing. The closing minutes set out a short workflow: define the joint requirement, filter against published specifications, then confirm the choice under real operating conditions. The narration stays with load paths, motion frequency and integration rather than reading out a data sheet, which is why the numbers below come from product documentation instead of spoken commentary.

How a Humanoid Robot Arm Actuator Is Specified Joint by Joint

Every humanoid robot arm actuator carries a different share of the arm mass and a different lever arm to the end effector. Before a candidate is opened, the film asks for output torque, speed, housing space, the mass the joint may add, duty cycle, and the feedback and control interfaces the system expects. Writing those six items down first keeps the search anchored to the mechanism.

Torque, speed and envelope come first

Rated torque is the continuous output within the thermal limits published for the unit; peak torque is a short-term value for acceleration and disturbance rejection. Both are quoted in Nm and neither means much without its condition. Speed decides whether the motion finishes in time, while diameter and length decide whether the module fits at all. A part that cannot fit the bore is out before its electrical ratings are compared.

Duty cycle, feedback and control compatibility

Holding a pose, reversing frequently and running a repeated pick-and-place cycle stress the same hardware differently. Encoder resolution and the mechanical and control interfaces decide whether a module can be integrated at all. These are compatibility questions rather than ranking questions, and they belong in the requirement list before a specification table is opened.

Neck Joint: Size and Weight Constraints

The neck carries the head assembly, so envelope and mass govern rather than raw output. The AK40-10 V3.0 KV170 is the actuator named in the video description for this position: 190 g, Ø53 × 40.2 mm, with 1.3 Nm rated and 4.1 Nm peak torque through a 10:1 stage. Those figures describe a fit problem as much as a torque problem — the head moves through a range of angles, and mass added at the top of the arm is carried by every joint below it.

Shoulder Joint: Rated vs Peak Torque

The shoulder drives the whole arm, so the load path includes arm mass, the payload lever arm and the acceleration demanded of the motion. The clip separates rated from peak torque here, and Continuous Torque vs Peak Torque: Duty Cycle, Thermal Limit, Torque-Speed Curve sets out why a short-term figure cannot size an axis that holds a load for long periods. A humanoid robot arm actuator at the shoulder is sized by the condition it has to hold, not only by the transient it can produce. The AK60-39 V3.0 is the actuator identified at this position, with 24 Nm rated and 72 Nm peak torque through a 39:1 stage, at 750 g and Ø79 × 67 mm.

Elbow Joint: Speed and Continuous Operation

The elbow flexes the forearm and carries the tool at its end. In repeated grasping and tool operation the film points to speed, acceleration, motion frequency and continuous running as equal partners to static load: torque alone does not settle this joint. The AK70-9 V3.0 KV60 is named here, with 8.5 Nm rated and 29.2 Nm peak torque through a 9:1 stage, at 540 g and Ø89 × 49 mm. A cycle repeating the same move many times a minute samples thermal behaviour, not just a one-off maximum, so the rated figure and its published conditions govern.

Wrist Joint: Output, Size and Feedback

The wrist adjusts the orientation of the hand or end effector inside a tight envelope. The film does not name an actuator for this position; it frames the trade as balancing output against size, weight, feedback resolution, and the mechanical and control interfaces at the end of the arm. With no model confirmed on screen, this article leaves the wrist as a requirement statement. A humanoid robot arm actuator sized on a guessed model would inherit that model’s ratio, encoder and connector choices — exactly the constraints the segment asks to check against the platform first.

Product Details

Published specifications for the three AK series actuators named in the CubeMars selection video
ModelRated torquePeak torqueRatioMassEnvelope
AK40-10 V3.0 KV1701.3 Nm4.1 Nm10:1190 gØ53 × 40.2 mm
AK60-39 V3.0 KV8024 Nm72 Nm39:1750 gØ79 × 67 mm
AK70-9 V3.0 KV608.5 Nm29.2 Nm9:1540 gØ89 × 49 mm

Figures follow the manufacturer product pages and the corresponding ToBMS product records, where torque is quoted in Nm under the published conditions. Three of the AK series members appear here because three are named in the clip; the rest of the range is not reproduced in this table.

Beyond the Specification Sheet: Manufacturing, Torque Testing and Validation

The last third of the film moves off the data sheet and onto the factory floor: gear machining, assembly and torque testing on a bench. A torque test result is reference data measured under the conditions stated for that test. Temperature, duty cycle and system adaptation still have to be checked on the target platform, which is why the clip closes on validation rather than on a specification table.

Reading a torque test result

A measured curve describes one setup: a supply, an ambient condition, a duration and a defined load. Changing any of them moves the usable region. Reading the curve alongside the rated and peak figures, then repeating the check on the assembled arm, turns a published number into a decision about one joint.

A Humanoid Robot Arm Actuator Selection Workflow

The closing sequence reduces to three steps applied in the same order for each joint.

Step 1: write the joint requirement

Record output torque, speed, envelope, mass budget, duty cycle, and feedback and control interfaces. State whether the load is held, reversed or repeated, because that decides which rating governs.

Step 2: filter against published specifications

Use envelope and mass as pass-or-fail gates, then compare torque ratings on shared axes. Select narrows candidates by weight and diameter, while Compare Products places surviving rows side by side. Keep the conditions attached to every figure.

Step 3: validate under real operating conditions

Confirm the chosen module on the assembled arm at the intended temperature, duty cycle and control bandwidth. The specification sheet and the operating point are not the same thing.

Explore on ToBMS

The Robotic Actuators category keeps the AK series alongside other integrated joint modules, and the platform pages carry technical detail and documentation for BLDC motors in one place. For the wider sizing question, BLDC Motors for Humanoid Robot: How to Match Torque, Speed and Size and How to Choose High Torque Robotic Actuator cover torque, speed and envelope at platform level. More manufacturer films in the Video section →

About the Manufacturer

CubeMars builds integrated robotic actuators that bring a BLDC motor, a reduction stage, drive electronics and position feedback into one housing. The CubeMars AK series spans compact joint modules through to units for load-bearing axes; the CubeMars profile collects the series and its documentation together. The film used here was published on the manufacturer channel as a selection guide.

Original Video

Video: How to Choose Actuators for a Humanoid Robot Arm | CubeMars AK (CubeMars, November 27, 2026, 3:17).

Frequently Asked Questions

What makes a humanoid robot arm actuator different at each joint?

The load path changes. The neck is bounded by size and mass, the shoulder by the lever arm of the whole arm, the elbow by speed and repeated operation, and the wrist by envelope and interface compatibility. One figure cannot describe all four, so the requirement list is written per joint.

Should rated torque or peak torque size the shoulder joint?

Rated torque governs a load that is held or repeated, because it is the continuous output inside the published thermal limits. Peak torque covers short transients such as acceleration. The duty cycle decides which one sets the size.

Does the video name an actuator for the wrist joint?

No. The wrist segment discusses output, size, weight, feedback and interfaces without naming a model, so this article leaves that joint as a requirement statement.

Where do the specification figures in this article come from?

From the official CubeMars product pages for the three named actuators, cross-checked against the corresponding ToBMS product records. The spoken commentary and the video description are treated as context, not as a source for figures.

Conclusion

The useful output of this clip is a method rather than a ranking: define what each joint has to do, filter on published specifications with the conditions attached, then validate on the assembled arm. Applied to neck, shoulder, elbow and wrist in turn, that method turns a humanoid robot arm actuator from a part number into a checked fit — and leaves the wrist open until a real requirement closes it.