Choosing a BLDC motor for rehabilitation robot work inverts the priorities that shape most motor selections. The movement a therapy device produces is slow by specification rather than by limitation, it is held for seconds rather than reached in milliseconds, and it is repeated for the length of a treatment session with a patient limb attached to the output. The actuator at the joint is therefore judged on the torque it can hold for a long time, the torque it can command accurately at very low speed, and how much of the load the patient can still feel through the gearing. This guide reads those three questions across nine of the actuators currently listed in the Robotic Actuators category, from the 190 g AK40-10 V3.0 KV170 to the 940 g AK10-9 V3.0 KV60, and sets them against the duty a Rehabilitation Robot joint actually imposes.
Quick Answer
A BLDC motor for rehabilitation robot duty is chosen on three figures that a general-purpose servo selection would not lead with. The first is continuous torque at the joint, because a therapy movement holds a limb against gravity for seconds at a time and the winding has to survive the hold rather than the transient. The second is the torque the actuator can command accurately at the speeds therapy uses, which sit far below the published no-load figure. The third is the reduction ratio, because the ratio decides both how much torque the joint has for a given motor and how much of the load reaches the patient through the output. Across the nine actuators gathered here, rated torque runs from 1.3 Nm on the AK40-10 V3.0 KV170 to 48 Nm on the AK80-64 KV80, mass runs from 190 g to 940 g, and the reduction ratio spans 6:1 to 64:1. That ratio spread, more than the torque spread, is what separates a light assistive joint from a loaded gait-training axis.
What a BLDC Motor for Rehabilitation Robot Must Deliver
The duty a rehabilitation joint imposes is narrow in speed and long in duration, and it arrives with a person attached to the output. Three properties follow from that, and they are the ones that separate a BLDC motor for rehabilitation robot joint from a motor chosen for a robot in the same torque class.
The therapy movement is slow by design
A therapy movement is described in degrees of range and seconds of duration, not in revolutions per minute. A knee or an elbow driven through its range over several seconds is a joint turning at tens of degrees per second, and behind a 9:1 stage that is a motor turning at a few hundred rpm. The published no-load speeds of the actuators in this group reach 800 rpm on the AK80-6 KV100, far above any working point a therapy movement calls for, so the selection does not run into the speed ceiling. It runs into the opposite end of the curve instead, where the useful questions are how evenly the actuator delivers torque at low speed and how finely the feedback resolves a small angle.
The load is a human limb, and it changes through the movement
Unlike a robot joint carrying a fixed payload, a rehabilitation joint carries a limb whose effective load changes with the geometry of the movement and with how much the patient contributes. A patient who assists reduces the torque the actuator has to supply; a patient who resists, or whose muscle tone rises during a stretch, increases it at a moment the controller has not planned for. A published rated torque is therefore a floor for the sizing calculation rather than a description of the worst case, and a published peak torque is the reserve that absorbs the unexpected. The two figures carry different spreads in this group: the AK80-6 KV100 publishes 12 Nm peak against 6 Nm rated, while the AK10-9 V3.0 KV60 publishes 53 Nm peak against 18 Nm rated and the AK80-64 KV80 publishes 120 Nm peak against 48 Nm rated.
Three figures that carry the requirement
Reduced to the smallest set, three published figures carry most of a rehabilitation selection. Rated torque is the continuous figure, and it is the one a held pose spends. The reduction ratio sets both the torque the joint sees and how transparent the joint feels to the patient. Continuous current is the electrical bill for the two, and it sizes the drive and the pack that travel with the device. Everything else in the specification, from the diameter to the pole count, is a constraint on fitting those three into the machine.
Low Speed and High Holding Torque in the Rehab Duty Cycle
Speed is where a BLDC motor for rehabilitation robot selection diverges furthest from every other robot application, and it is the first thing the Rehabilitation Robot duty fixes. The working point is not fast, and the torque at that point is held for a long time, which turns two published figures into the centre of the selection.
Working torque sits at the bottom of the speed range
The rated speed column of the table below runs from 23 rpm on a 24 V bus at the AK80-64 KV80 to 603 rpm on the AK80-6 KV100, and a therapy joint that creeps through a range of motion spends its time well under all of them. The low-speed actuators in this group are not a compromise for that duty; the low speed is the design. A 36:1 stage on the AK45-36 V3.0 KV80 turns 40 rpm at the output on a 24 V bus, and a 64:1 stage on the AK80-64 KV80 turns 23 rpm, both of which sit inside the range a therapy movement covers without any further reduction.
Holding a limb against gravity is continuous torque
A pose held against gravity draws current continuously, and current is heat. In a rehabilitation device, holding is not an interlude between movements; on a continuous passive motion machine or a static stretch rig it is most of the session. The figure that governs is therefore rated torque, and the way to read it is against the published rated current that goes with it. The AK80-64 KV80 publishes 48 Nm rated at 7 A, while the AK10-9 V3.0 KV60 publishes 18 Nm rated at 10.7 A. The first holds more than twice the torque for the lower current, and the reason sits in the ratio between them rather than in the motors.
Repetition sets the thermal duty, not the peak
A treatment session repeats the same movement many times, and the thermal state of the winding at the start of each repetition is set by the one before it. A continuous rating is a thermal statement, and it is made against a mounting condition that the actuator record does not fully carry. Inside a device with its own enclosure and its own heat path, how much of that rating survives is a question for the manufacturer, and it belongs at the front of the requirements list when a joint is expected to hold a high torque for a large part of the session.
Why a Safe Joint Must Stay Backdrivable Under Load
A rehabilitation joint shares its output with a person. A therapist guiding a limb by hand, or a patient attempting the movement without assistance, applies torque at the same shaft the actuator drives, and the joint has to accept that torque rather than fight it. How far it does so is set by the reduction stage, not by the motor on its own.
Backdrivability is set by the ratio and the stage
The reduction ratio multiplies motor torque up to joint torque and divides joint motion down to motor motion in the same proportion, and it does the same to the torque a person applies at the output. A single planetary stage of 64:1 on the AK80-64 KV80 is far harder to drive from the output than the 6:1 stage on the AK60-6 V3.0 KV80 or the AK80-6 KV100, and the difference is mechanical rather than electronic. A joint that has to be moved by a hand, or that has to yield when a patient pushes against it, is the case that calls for a backdrivable BLDC motor, and the ratio is where the trade between torque multiplication and that freedom is struck.
What a high reduction ratio takes away
The same ratio that multiplies torque works against two other properties. It raises the friction and the backlash of the stage that the output has to overcome before any load is transmitted, and it changes the effective inertia the patient feels at the joint. The published backlash figures in this group sit between 0.18° on the AK80-64 KV80 and 0.3° on the AK40-10 V3.0 KV170, the AK45-10 V3.0 KV75 and the AK70-9 V3.0 KV60, with the AK45-36 V3.0 KV80, the AKH70-16 V1.0 KV41 and the AK80-6 KV100 publishing 0.2° and 0.22° between them. Backlash is felt at the joint as a dead band at the start of every reversal, and in a rehabilitation device a dead band of that size is visible in the movement rather than only measurable in it.
Where the actuator sits in a patient contact path
The safety argument does not end at the actuator. A device that holds a limb also carries the limits, the torque command range, the emergency stop and the mechanical end stops, and those are part of the machine rather than the module. What the actuator contributes is that it can be commanded to a bounded torque and that it does not lock when the command is removed. Both of those are properties of an integrated actuator with its own driver, and both are the reason a sealed module is often the simpler starting point for a joint that has to stay compliant while a person is attached to it.
Force Control and the Torque Band Behind It
Assistive therapy is a torque problem before it is a position problem. A joint that helps a patient complete a movement has to add torque in proportion to what the patient is already doing, and that requires a rehabilitation robot actuator whose drive can be commanded in torque and trusted at small values.
Torque control needs an estimate the drive can act on
A torque-mode command is only as good as the estimate of output torque the drive works from, and that estimate is built from phase current and from the position feedback the actuator carries. The sealed modules in this group put the motor, the reduction stage and the driver inside one housing, and the record states the feedback arrangement where it publishes one: the AK10-9 V3.0 KV60 and the AK70-9 V3.0 KV60 are both documented with dual encoders, which is the arrangement that supports a torque loop rather than only a position loop.
Resolution at the joint, not at the rotor
The movement a therapy asks for is small at the output and larger on the motor side, and the reduction ratio is the multiplier between them. A joint asked to resolve a fraction of a degree at the output is asking the feedback on the motor side to resolve that fraction multiplied by the ratio, which is why a high-ratio actuator is not automatically the easier one to control finely. The published output speeds in this group already make the point: the same actuator that holds 48 Nm at 23 rpm on the AK80-64 KV80 is holding it at the slow end of the range, where the control loop has the most time and the least signal to work with.
Compliance, impedance and assist-as-needed modes
Impedance control, admittance control and series elastic elements are properties of the control layer rather than entries in an actuator record, and none of them is bought with the module alone. What the actuator has to provide is the bandwidth to follow a torque command and the low friction to let that command be small. A joint whose friction and backlash dominate at low torque cannot be made compliant by software, which is the practical reason the ratio and the backlash figures carry as much weight in a rehabilitation selection as the torque figure does.
Continuous Holding Torque Against Peak Torque in a Session
The two torque figures on an actuator label answer two different questions, and a rehabilitation duty spends most of its time on one of them.
Rated torque is the figure a session spends
Rated torque is the largest figure the manufacturer publishes for continuous operation, and it is the one a held pose or a repeated slow movement spends. In this group it runs from 1.3 Nm on the AK40-10 V3.0 KV170 to 48 Nm on the AK80-64 KV80, with the middle of the range occupied by the AK70-9 V3.0 KV60 at 8.5 Nm, the AK45-36 V3.0 KV80 at 8 Nm and the AK80-6 KV100 at 6 Nm. A joint that supports a limb, resists gravity over a range of motion or holds a position against a stretch is working in the rated column for the whole of that period.
Peak torque covers the transition, not the hold
Peak torque is a short excursion, and the published peak currents behind it are several times the rated currents in the same record. The AK10-9 V3.0 KV60 publishes 31.9 A peak against 10.7 A rated and the AK70-9 V3.0 KV60 publishes 23.8 A peak against 6.25 A rated, which is a difference no winding can hold for long. Peak torque belongs to the moments a rehabilitation movement changes direction, catches a limb that has begun to fall, or absorbs a sudden change in muscle tone. Using it as a working point inside a session moves the joint onto a rating the manufacturer did not publish for continuous service.
Current is the number that sizes the drive and the pack
An integrated actuator carries its driver inside the housing, but the current still has to arrive from a pack and a bus that the device carries, and a rehabilitation device is often portable. The published rated currents in this group range from 1.9 A on the AK45-10 V3.0 KV75 to 10.7 A on the AK10-9 V3.0 KV60, and a device with several joints multiplies that figure by the number of axes it moves at once. Current is therefore the bridge between the mechanical requirement at the joint and the electrical design of the whole device, and it is worth fixing early for that reason.
A Specification Set for Rehabilitation Joints, Light to Loaded
The table below gathers the nine actuators discussed here on the columns that decide a rehabilitation joint. Every value is the figure the manufacturer publishes for that actuator.
| Model | Reduction Ratio | Rated Torque | Peak Torque | Rated Current | Output Speed | Weight |
|---|---|---|---|---|---|---|
| AK40-10 V3.0 KV170 | 10:1 | 1.3 Nm | 4.1 Nm | 2.7 A | 370 rpm | 190 g |
| AK45-10 V3.0 KV75 | 10:1 | 2.5 Nm | 7 Nm | 1.9 A | 120 rpm | 262 g |
| AK45-36 V3.0 KV80 | 36:1 | 8 Nm | 24 Nm | 2 A | 40 rpm | 349 g |
| AK60-6 V3.0 KV80 | 6:1 | 3 Nm | 9 Nm | 3.8 A | 233 / 490 rpm | 380 g |
| AK80-6 KV100 | 6:1 | 6 Nm | 12 Nm | 9.7 A | 603 rpm | 485 g |
| AK70-9 V3.0 KV60 | 9:1 | 8.5 Nm | 29.2 Nm | 6.25 A | 260 rpm | 540 g |
| AK80-64 KV80 | 64:1 | 48 Nm | 120 Nm | 7 A | 23 / 48 rpm | 850 g |
| AKH70-16 V1.0 KV41 | 16:1 | 26 Nm | 78 Nm | 6.5 A | 90 rpm | 879 g |
| AK10-9 V3.0 KV60 | 9:1 | 18 Nm | 53 Nm | 10.7 A | 235 rpm | 940 g |
Reduction ratio, rated torque, peak torque, rated current, output speed and weight as published by the manufacturer (CubeMars). Where an output speed carries two values, they are the 24 V and 48 V working points in that order. Rated torque is the continuous figure and peak torque is a short-duration value. Winding, thermal and mounting data for each actuator are on its manufacturer product page.
Read down the ratio column and the group divides into three bands rather than nine points. Three actuators work at 10:1 or below on a 24 V bus, the AK40-10 V3.0 KV170, the AK45-10 V3.0 KV75 and the AK60-6 V3.0 KV80, all of them under 4 Nm rated and under 400 g. Three work at 9:1 on 48 V, the AK70-9 V3.0 KV60, the AK10-9 V3.0 KV60 and the AK80-6 KV100 at 6:1 on the same bus, and those sit between 6 Nm and 18 Nm rated. The last band is the two actuators that use a long reduction stage to reach a high torque from a small motor, the AK45-36 V3.0 KV80 at 36:1 and the AK80-64 KV80 at 64:1, with the AKH70-16 V1.0 KV41 at 16:1 filling the gap above the 9:1 group. Read across instead, and the current column separates the bands again: the light 10:1 group needs between 1.9 A and 3.8 A to hold its torque, while the 48 Nm of the AK80-64 KV80 costs 7 A and the 18 Nm of the AK10-9 V3.0 KV60 costs 10.7 A.
Reading the Range from Hand and Wrist to Gait Training
The four bands below run from the smallest joint a rehabilitation device is likely to drive to the axis that carries a walking patient, and each band is defined by a duty rather than by a number. All nine sit in the Robotic Actuators category, and the Rehabilitation Robot page is where this application is documented on the platform.
The 190 g and 262 g end: hand, wrist and finger axes
The AK40-10 V3.0 KV170 publishes 1.3 Nm rated and 4.1 Nm peak from a 190 g body at 53 mm, and the AK45-10 V3.0 KV75 publishes 2.5 Nm rated and 7 Nm peak from 262 g at the same 53 mm diameter. Both run on a 24 V bus and both use a 10:1 stage, and both are sized for the joints at the end of a limb, where the mass the patient has to carry through a movement is charged directly against the therapy. A finger or wrist orthosis that has to be worn rather than mounted on a frame is the case these two are built for.
The 349 g and 380 g step: elbow and light ankle joints
The AK45-36 V3.0 KV80 takes the same small frame and puts a 36:1 stage behind it, publishing 8 Nm rated and 24 Nm peak at only 40 rpm of output speed on 24 V, which is a torque figure far above its mass class at the cost of speed. The AK60-6 V3.0 KV80 takes the opposite position in the same envelope, publishing 3 Nm rated and 9 Nm peak through a 6:1 stage at 380 g, with a rated speed of 233 rpm on 24 V and 490 rpm on 48 V. An elbow assist that has to move quickly through a range and an ankle joint that has to hold a torque slowly are the two duties that separate them.
The 485 g and 540 g middle: shoulder and knee assistance
The AK80-6 KV100 publishes 6 Nm rated and 12 Nm peak from 485 g at a 98 mm diameter, with the highest output speed in this group at 603 rpm, and the AK70-9 V3.0 KV60 publishes 8.5 Nm rated and 29.2 Nm peak from 540 g at 89 mm with a 9:1 stage and a documented dual-encoder arrangement. Both sit at the scale where a shoulder or a knee can be driven through a therapy range, and the choice between them comes down to whether the joint needs speed at a modest torque or torque at a modest speed.
The 850 g to 940 g end: gait training and loaded joints
The AK80-64 KV80 uses a 64:1 stage to publish 48 Nm rated and 120 Nm peak from 850 g, and the AKH70-16 V1.0 KV41 publishes 26 Nm rated and 78 Nm peak from 879 g with a 16:1 stage and a hollow shaft through the axis. The AK10-9 V3.0 KV60 sits at the top of the mass column at 940 g with 18 Nm rated and 53 Nm peak and a documented dual-encoder arrangement. These are the axes that carry a standing patient or move a whole limb against gravity, and the 64:1 and 16:1 stages are what make that possible without a heavier motor.
The Two Actuators Behind Published Rehabilitation Research
A rehabilitation joint is usually specified before any published deployment exists to point at, which makes the documented cases worth reading closely. One is carried in the record here: a muscular atrophy rehabilitation system from the Université de Sherbrooke, featured by CubeMars, which uses two of the actuators in this comparison to produce precise stretching movements.
CubeMars shows the Sherbrooke system using two AK-series actuators to deliver precise stretching movements for patients with muscular atrophy. It is the clearest published illustration of the two ends of the range this guide covers being used for the same clinical purpose.
ToBMS video pageWatch on YouTubeThe two units are the AK10-9 V3.0 KV60 at 18 Nm rated and the AK80-64 KV80 at 48 Nm rated, and the pair maps onto the two heaviest bands of the table above rather than onto one point in it. The reason a single system carries both is worth reading out of the figures: a stretching movement needs a torque the joint can hold without the winding heating, and it needs a range of motion the joint can be moved through by the device and by the therapist. Inside one machine, different axes can therefore land on different ratios, and the 9:1 unit and the 64:1 unit are not alternatives to each other but complements: a rehabilitation robot actuator is chosen per axis rather than per device.
Matching an Actuator to a Training Mode
A rehabilitation joint is specified against a mode of therapy, and the modes differ in how much of the work the actuator does and how quickly the load changes. For a BLDC motor for rehabilitation robot application, the mode is a better starting point than the torque figure, because it fixes how the patient and the actuator share the load.
Passive and continuous passive motion
In passive mode the device moves the limb and the patient contributes nothing, so the actuator carries the whole load and the load changes only with the geometry of the movement. The requirement is a torque held for the length of the pass, at a speed low enough that the movement reads as smooth, and the figures that decide it are the rated torque and the rated current of the actuator. A joint built for passive movement alone can use the longest ratio in the group, because nothing in the duty asks for speed.
Active-assisted and assist-as-needed
In active-assisted mode the patient contributes and the device fills the gap, and the gap changes from repetition to repetition. This is the mode that asks for torque control rather than position control, and it is the mode where a documented dual-encoder arrangement on the AK10-9 V3.0 KV60 or the AK70-9 V3.0 KV60 becomes relevant, because a torque loop needs feedback that reflects both the motor side and the output. It is also the mode where low friction and low backlash matter most, since the assistance has to be small enough to stay under the patient's own effort.
Resistance and strength training
In resistance mode the device opposes the movement rather than producing it, and the actuator works as a programmable brake. The load is still continuous, and it is applied in the direction the patient is pushing, which puts the joint in the part of its range where the winding is drawing current without the joint moving. Rated current rather than rated speed is the figure that bounds this duty, and the ratio matters for a different reason than in passive mode: a long stage lets a small motor hold a large resisting torque, which is what the AK45-36 V3.0 KV80 at 36:1 and the AK80-64 KV80 at 64:1 are arranged to do.
Gait training and body-weight support
In gait training the joint follows a walking cycle rather than a single range of motion, and the load alternates between the stance phase, where the joint holds, and the swing phase, where it moves. That alternation is the reason a gait axis usually lands on the heavier end of the table: the holding phase needs the rated figure and the swing phase needs enough speed to keep up with a cadence, and the two together push the selection toward a ratio that buys torque without losing all of the speed. The AKH70-16 V1.0 KV41, with a hollow shaft through the axis for cabling the joint above and below it, and the AK10-9 V3.0 KV60 at 53 Nm peak are the two arrangements this duty tends to reach for.
Selection checklist
The duty and the safety case
- Write the continuous torque the joint has to hold and the duration of each hold, before looking at any model number.
- Write the peak torque the movement needs at a direction change, and keep it separate from the holding figure.
- Decide whether the joint has to be moved by a hand or yield under a patient's push, and fix the reduction ratio against that answer.
- Confirm the torque command range and the limits the machine will impose, since those belong to the device rather than the actuator.
Mechanics and the patient interface
- Check the published mass against how the device is carried, and charge distal mass against the movement rather than against the frame.
- Check the published backlash against the smallest movement the therapy has to resolve.
- Check the published diameter and length against the envelope the limb allows, before comparing torque figures.
- Where conductors have to cross the joint, check whether a hollow shaft through the axis is available.
Integration, feedback and the drive
- Confirm the feedback arrangement published for the actuator, and whether it supports a torque loop rather than only a position loop.
- Convert the holding torque into a rated current with the published figure, then multiply it across the number of axes the device moves at once.
- Fix the bus voltage from the speed the movement needs at the torque it needs, using the published output speed column.
- Ask the manufacturer for the thermal resistance and the mounting condition behind the continuous rating, since the record does not carry them.
Frequently asked questions
QCan a rehabilitation joint hold a limb at its rated torque for a whole session?
The published record separates rated torque from peak torque for that reason. Rated torque is the continuous figure and is the one a held pose spends; peak torque is a short excursion. In this group the peak figure comes with a peak current several times the rated current, such as 31.9 A against 10.7 A on the AK10-9 V3.0 KV60 and 23.8 A against 6.25 A on the AK70-9 V3.0 KV60, and a winding cannot sustain that difference. A session belongs in the rated column, and the duration it can be sustained for depends on the mounting and the enclosure, which are device questions rather than actuator questions.
QDoes a higher reduction ratio make a rehabilitation joint safer?
It buys torque and spends transparency. The same ratio that turns a small motor into a 48 Nm joint on the AK80-64 KV80 also makes the joint harder to drive from the output, which is the property that matters when a therapist guides the limb by hand or a patient pushes against the device. The published backlash figures move in the same direction in a subtle way rather than a straight line, with 0.3° on the AK40-10 V3.0 KV170 at 10:1 and 0.18° on the AK80-64 KV80 at 64:1, so a long stage is not automatically the looser one. The selection is a trade rather than a ranking.
QWhat feedback does a rehabilitation actuator need at the joint?
It depends on the mode of therapy. A BLDC motor for rehabilitation robot joint that only executes a programmed pass at low speed needs position feedback accurate enough to make the movement smooth. A joint that assists the patient has to run a torque loop, and that loop is built from phase current together with position feedback from both the motor side and the output. The record states the arrangement where it publishes one, and the AK10-9 V3.0 KV60 and the AK70-9 V3.0 KV60 are documented with dual encoders for that reason.
QHow much actuator mass can a wearable rehabilitation device carry?
There is no published limit, and the useful way to read the question is against where the mass sits. In this group the small end starts at 190 g on the AK40-10 V3.0 KV170 and 262 g on the AK45-10 V3.0 KV75, both at a 53 mm diameter, and the heavy end reaches 940 g on the AK10-9 V3.0 KV60. A joint at the hand or the wrist pays for its own mass through every movement the patient makes, while a joint at the shoulder or the hip is closer to a fixed frame. The published torque and mass columns read together are the practical comparison, and the reduction ratio explains why two actuators of similar mass can hold very different torques.
Official resources
CubeMars documents the AK range on its own site, and each actuator in this comparison has an official page carrying its full specification, reduction stage and mounting drawing. The manufacturer’s product range is the entry point, and the two units named in the rehabilitation system are documented individually: the AK10-9 V3.0 KV60 and the AK80-64 KV80. The CubeMars manufacturer profile collects the same range on ToBMS, and product documentation across the platform’s categories is gathered under Resources. The manufacturer remains the source of truth for winding options, thermal ratings and feedback variants; ToBMS keeps the discovery and comparison layer, and every figure used in this guide is a published value held in the platform’s product records.
Where to go next
The closest companion to this guide is Exoskeleton Actuators: Three CubeMars QDD Actuators from 260 g to 1.4 kg, which reads the same joint duty for a wearable device, and BLDC Motors for Exoskeleton: Frameless Torque Motor vs Integrated Actuator takes up the earlier decision of whether the joint should be a bare stator and rotor kit or a sealed module. For the actuator class itself, Robotic Actuators: How to Choose the Right Integrated Actuator for Robot Joints works through the full specification set, and Choosing a Joint Module: Five CubeMars Actuators from 190 g to 1.4 kg follows the light end of the same range in more detail. Where the application sits next to this one, BLDC Motors for Humanoid Robot: How to Match Torque, Speed and Size and What to Look For in a BLDC Motor for Collaborative Robot Arm cover the neighbouring duties.
To shortlist rather than to research, start from the full Robotic Actuators category, filter candidates by torque, ratio and mass in Select, then set them against each other in Compare Products. Where the joint has to be a bare kit rather than a sealed module, the Frameless Torque Motors category carries that end of the range, and the direct-drive alternative sits in Quasi Direct Drive Actuators. The Rehabilitation Robot page is the application entry point for this duty, and the neighbouring Joint Module, Collaborative Robot Arm, Humanoid Robot and Quadruped Robot pages cover the applications that share these actuators.